EPSON Stylus Color 900 Revision C
Adjustment Adjustments 144
Figure 5-22. Recovery from Unmagnetized Status
13. The following screen appears and the carriage automatically moves
toward the 80th column.
Figure 5-23. Screen after “Head Angular Adjustment” is Selected
14. Loosen the screw securing the head fixing plate on the right side of
the carriage unit by turning it 90
° - 180°. (Do not remove it
completely.)
Figure 5-24. Screw Securing the Head Fixing Plate on the Right
15. Press the Enter key in the screen (Figure 5-23).
Did you loosen the screw on the left side of the CR?
Yes
No
E s c: P re v iou s U p /D o w n a rro w s: S e le ct E n te r: O K
After it takes 3 m inutes.
Did you loosen the screw on the left side of the CR?
Yes
No
E s c: P re v iou s U p /D o w n a rro w s: S e le ct E n te r: O K
The printer has been left alone for 3 m inutes. The pum p, ASF m otor
hasn't been properly m agnetized, and carriage will not m ove.
Please press the Enter key.
Now perform CL1 in order to recover the m otor's m agnetized state.
CL1 takes about 90 seconds, and all keys are ignored during this operation.
Press the Enter key.
1. After you have moved the angular adjustment lever,
2. push the color I/C from front side by using fine driver or tweezers.
3. Please gently tighten the screws the right side at first, and press
th e E n te r ke y.
4. The head angular adjustm ent pattern will be printed.
E n te r: O K
In ca se o f 1 st p rin t:
C ap unit
Screw (right) securing the Head Fixing Plate