Toshiba SL-9000-FFH-QR Scale User Manual


 
15. ERROR MESSAGE TABLE
15. ERROR MESSAGE TABLE
15- 3
CMT Operation Mode
LON System Mode
M: Master scale BM: Backup master scale S: Satellite scale
Message Cause Solution
Mismatch of the model type.
Mismatch of the base unit.
Mismatch of the VERSION.
Mismatch of the
TRANSMITTING DATA.
MISMATCH SCALE SPEC
Mismatch of the scale capacity.
Press the key
Parity error
Framing error
Overrun error
Data error
BAD TAPE OR CMT
Two or More Hardware error
Press the key
TIME OUT ERROR Time out error Press the key.
Message Cause Solution M BM/S
COMMUNICATION
ERROR
1.The power of the master or
backup master scale is not turned
ON.
They are not connected with each
other or in off-line state.
2.LON cable is broken.
1. Turn the power of the master
or backup master scale ON.
Connect them with each other
or turn the scale in-line.
2. Call your authorized service
representative.
SEQUENCE ERROR The power was not turned OFF and
ON again after setting ID #.
Turn the power switch OFF and
ON again.
SEQUENCE NO.
ERROR
Text data number is incorrect. Call your authorized service
representative.
MASTER BUSY Registration job is performed on a
satellite scale while reset job is
performed on the master scale.
1. Quit reset job on the master
scale.
2. Quit registration job on the
satellite scale.
BACKUP MASTER
NOT RESET
The backup master does not have
same PLU with the master scale.
Down load PLU from the master
to the backup master scale.
Then run the reset operation
again.
TEXT ERROR ## 1.Error text is found.
02: Sequence No. error
05: LRC error
08: Text error
09: Command error
2.The master scale differs from
other scale in ROM version.
Call your authorized service
representative.
CLEAR
CLEAR
CLEAR