Sentry Industries Sentry 2.0 Thermometer User Manual


 
26
Appendix B: Preset Standard
Cone-Fire Schedules - °F
These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your
changes. Then load your new schedule into Ramp-Hold.
Low Fire Cones °F
Segment 1 Segment 2
Cone Rate 1 Temp. 1 Rate 2 Temp. 2
022 396 979 108 1087
021 396 1004 108 1112
020 396 1051 108 1159
019 396 1144 108 1252
018 396 1211 108 1319
017 396 1252 108 1360
016 396 1314 108 1422
015 396 1348 108 1456
014 396 1377 108 1485
013 396 1431 108 1539
012 396 1474 108 1582
011 396 1499 108 1607
Medium Fire Cones °F
Segment 1 Segment 2 Segment 3 Segment 4
Cone Rate 1 Temp. 1 Rate 2 Temp. 2 Rate 3 Temp. 3 Rate 4 Temp. 4
010 324 1022 153 1112 180 1549 108 1657
09 324 1022 153 1112 180 1580 108 1688
08 324 1022 153 1112 180 1620 108 1728
07 324 1022 153 1112 180 1681 108 1789
06 324 1022 153 1112 180 1720 108 1828
05 324 1022 153 1112 180 1780 108 1888
04 324 1022 153 1112 180 1837 108 1945
03 324 1022 153 1112 180 1879 108 1987
02 324 1022 153 1112 180 1908 108 2016
01 324 1022 153 1112 180 1938 108 2046
High Fire Cones °F
Segment 1 Segment 2 Segment 3 Segment 4
Cone Rate 1 Temp. 1 Rate 2 Temp. 2 Rate 3 Temp. 3 Rate 4 Temp. 4
1 324 1022 153 1112 162 1863 108 2079
2 324 1022 153 1112 162 1872 108 2088
3 324 1022 153 1112 162 1890 108 2106
4 324 1022 153 1112 162 1908 108 2124
5 324 1022 153 1112 162 1951 108 2167
6 324 1022 153 1112 162 2016 108 2232
7 324 1022 153 1112 162 2046 108 2262
8 324 1022 153 1112 162 2064 108 2280
9 324 1022 153 1112 162 2084 108 2300
10 324 1022 153 1112 162 2129 108 2345