Sentry Industries Sentry 2.0 Thermometer User Manual


 
Chapter 7
Error Messages
Error messages are accompanied by an alarm.
Non-interrupting messages do not stop the firing. Ter
-
minating error messages do.
FTC, FTH, LTdE, and HTdE error messages are based
upon the setting in the Temperature Deviation (TEdE)
option. See page 20.
For detailed diagnostics and maintenance, see “Sentry
Trouble Shooter,” a separate publication.
Non-Interrupting
Error Messages
Press ENTER to silence the alarm. (Do not press stop to
silence the alarm.) The error message will remain but the
kiln will continue firing.
FTC / Failed to Cool
During a cooling ramp, the kiln cannot cool as quickly as
programmed. The temperature is above the deviation
setting. (See Temperature Deviation, page 20.)
Program a slower cooling rate.
FTH / Failed to Heat
During a heating ramp, the kiln cannot heat as quickly as
programmed. The temperature is below the deviation
setting. (See Temperature Deviation, page 20.)
Check for worn or burned out elements, defective relays,
low voltage and defective thermocouple. Program a slower
rate.
LTdE / Low Temperature Deviation
During aramp ora hold,the temperatureis belowthe de
-
viation setting.
Check for worn or burned out elements, defective relays,
low voltage and defective thermocouple.
PF / Power Failure
PF alternating with normal display means the power
failed during firing. After power was restored, the firing re
-
sumed.
Terminating Error
Messages
BAdP / Bad Programming
Thismessage appearswhen aRamp-Holdfiring hasbeen
programmed with 0 rate in the first segment.
ETH / Electronics Too Hot
The circuit board temperature is above 185°F/85°C.
Open windows and use a fan to circulate air in the room
before firing the kiln or furnace. If you have more than one
kiln in the room, place them farther apart. Never allow the
firing room temperature to exceed 110°F/43°C. (Measure
room temperature three feet away from the kiln.)
FAIL / Thermocouple Failure
Defective Thermocouple
Disconnected Thermocouple Lead Wires
Defective Board
Electrical Noise
FTL / Firing Too Long
The temperaturerise isless than27°F/15°C perhourand
the firing time is four hours longer than the current seg-
ment was programmed to fire.
Check for worn or burned out elements, defective relays,
low voltage and defective thermocouple.
HTdE / High Temperature Deviation
During aramp ora hold, thetemperature isabove thede-
viation setting.
Check for a stuck relay.
PF 2 / Power Failure
The power failed. The kiln temperature was below
212°F/100°C when the power came back on.
The kiln will not resume firing.
PF 3 / Power Failure
This message appears when two conditions are met:
1 The power failed during the final segment of a
Cone-Fire firing.Or, the powerfailed during thefi
-
nal segment of a Ramp-Hold firing that included a
108°F/60°C rate in the final segment.
2 The temperature dropped 72°F/40°C while the
power was off.
The kiln will not resume firing.
22