VII. OPERATION
Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power interface
between the power module, the lights, and/or the power seat actuator.
Sleep Mode
Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main
power if the joystick is not moved in any direction for a period of time. The battery condition meter lights on the keypad
indicate sleep mode by blinking once every 25 seconds. To restore power and continue, push the on/off key twice.
Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with
your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are
flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is
flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing meter. When you get a trouble code, contact your authorized Pride provider.
FLASHING LIGHTS DIAGNOSIS SOLUTION
10 High Battery Voltage Check batteries.
9 Solenoid Brake Fault Check motor/brake wiring.
8 Possible Controller Fault See authorized Pride provider.
7 Possible Joystick Fault See authorized Pride provider.
6 Inhibit Active Unplug charger. Check connections.
5 Right Motor Wiring Fault Check right motor wiring.
4 Right Motor Disconnected Check right motor wiring.
3 Left Motor Wiring Fault Check left motor wiring.
2 Left Motor Disconnected Check left motor wiring.
1 Low Battery Voltage Check batteries/battery wiring.