Pride Mobility Jet10Ultra Mobility Aid User Manual


 
Jet 10 Ultra/RevA/Apr04 www.pridemobility.com 39
Figure 27. Battery Wiring Diagram
IX. CARE AND MAINTENANCE
13. Remove the back battery.
14. Place a new back battery on the battery tray. Make sure that
the terminals are facing forward.
15. Fasten the reusable strap around the back battery.
16. Connect the wiring harnesses to the back battery. See figures
26 and 27.
WARNING! Prevent injury. Use only the
quick disconnect harness supplied with
the Jet 10 Ultra. It has a thermal fuse
on each lead.
17. Place a new battery in the front of the battery tray. Make sure that the terminals are facing backward.
WARNING! Prevent injury. Make sure you tighten the fasteners so that the connections are secure.
18. Fasten the reusable strap around the front battery.
19. Connect the wiring harnesses to the front battery. See figures 26 and 27.
20. Slide the battery tray back into the power base.
NOTE: Make sure that the power pod is out of the way when reinstalling the batteries.
21. Reinstall the foot platform.
22. Reconnect the battery connector.
23. Reinstall the rear shroud and tighten the fasteners.
24. Charge the batteries. See VII. Batteries and Charging.
When to See Your authorized Pride Provider for Service
The following symptoms could indicate a serious problem with your power chair. If necessary, contact your authorized
Pride Provider. When calling, have the model number, serial number, nature of the problem, and the error code if available.
n Motor noise n Frayed harnesses
n Cracked or broken connectors n Uneven wear on any of the tires
n Jerky motion n Pulling to one side
n Bent or broken wheel assemblies n Does not power up
n Powers up, but does not move
Corrective Maintenance
If the battery condition meter does not light up when you turn on the power:
n Check the harness connections. Make sure they are tight.
n Check the circuit breaker. Reset it if necessary.
n Check the battery connections.
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are available
at automotive parts stores. Disconnect both batteries before load testing and follow the directions that come with the load
tester. If either one of the batteries fails the load test, replace both of them. If your power chair still does not power up,
contact your authorized Pride Provider.