VII. CARE AND MAINTENANCE
To replace the batteries:
1. Turn off the power to the controller.
2. Make sure that the power chair is in drive mode. See III. “Your Power Chair.”
3. Disconnect the controller connector from the power base.
4. Remove the seat.
5. Remove the body shroud.
6. Loosen and remove the nuts on the positive battery terminals of each battery first.
7. Remove the wires from each terminal.
8. Loosen and remove the nuts on the negative battery terminals of each battery.
9. Remove the wires from each terminal.
10. Remove the old batteries.
11. Reinstall the wiring harness on each new battery. Make sure that you connect the red wire to the positive (+)
battery terminal and the black wire to the negative (-) battery terminal of each battery.
WARNING! Make sure you tighten the fasteners so that the connections are secure.
12. Install the new batteries into your power chair with the terminal sides of the batteries facing inward, toward
each other.
13. Connect the battery quick disconnects according to the battery wiring diagram. See figure 22. (Connect the
matching colors from the battery cable quick disconnect to the battery cable harness.)
14. Reinstall the body shroud.
15. Reinstall the seat.
16. Charge the batteries. See VI. “Batteries and Charging.”
When to See Your Authorized Pride Provider for Service
The following symptoms could indicate a serious problem with your power chair. If necessary, contact your
authorized Pride Provider. When calling, have the model number, serial number, nature of the problem, and the
error code if available.
Motor noise
Frayed harnesses
Cracked or broken connectors
Uneven wear on any of the tires
Jerky motion
Pulling to one side
Bent or broken wheel assemblies
Does not power up
Powers up, but does not move
Corrective Maintenance
If the battery condition meter does not light up when you turn on the power:
Check the harness connections. Make sure they are tight.
Check the circuit breaker. Reset it if necessary.
Check the battery connections.
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are
available at automotive parts stores. Disconnect both batteries before load testing and follow the directions that
come with the load tester. If either one of the batteries fails the load test, replace both of them. If your power chair
still does not power up, contact your authorized Pride Provider.