Pride Mobility 1400 Wheelchair User Manual


 
Jazzy 1400/Rev C/Sept02 www.pridemobility.com 33
VIII. OPERATION
Code Title Corrective Action
1 DX Module Fault Turn the controller off, then on again. If this does not work, check
the connections at the joystick, the power module, and any other
accessory module that your Jazzy may have. If this still does not
work, contact your local Jazzy provider.
2 DX Accessory Fault Power down the Jazzy and check all the connections to your
accessories. You may have a shorted circuit in one of these
connections (e.g., a light bulb is shorted or open).
3 Left Motor Fault Check the connection between the power module and the left
motor. There may be a short or bad connection. The motor itself
may be bad.
4 Right Motor Fault Check the connection between the power module and the right
motor. There may be a short or bad connection. The motor itself
may be bad.
5 Left Park Brake Fault Check the connection between the power module and the left
motor. There may be a short or bad connection.
6 Right Park Brake Fault Check the connection between the power module and the right
motor. There may be a short or bad connection.
7 Low Battery Fault Check the battery connections and terminals. Check that the circuit
breaker is not tripped. Reset it if necessary.
8 Overvoltage Fault Contact your service center.
9 CANL Fault Contact your service center.
10 CANH Fault Contact your service center.
11 Stall Timeout Fault Turn the system off, then turn it on again.
12 Module Mismatch Contact your service center.
Before you perform any of the electrical connection corrective actions listed in the following table, make sure that
you have fully charged batteries and you power down the system. In each case, if the corrective action does not
work, contact your service center.