NCT Group 2000M Microscope & Magnifier User Manual


 
6 The Feed
46
The Table below shows the maximum programmable range of values at address F, for various
cases.
input
units
output
units
increment
system
value range of address F unit
mm mm
IS-A 0.001 - 250000 mm
or
deg/min
IS-B 0.0001 - 25000
IS-C 0.00001 - 2500
IS-A 0.0001 - 5000 mm
or
deg/rev
IS-B 0.00001 - 500
IS-C 0.000001 - 50
inch mm
IS-A 0.0001 - 9842.5197 inch
or
deg/min
IS-B 0.00001 - 984.25197
IS-C 0.000001 - 98.25197
IS-A 0.00001 - 196.85039 inch
or
deg/rev
IS-B 0.000001 - 19.685039
IS-C 0.0000001 - 1.9685039
inch inch
IS-A 0.0001 - 25000 inch
or
deg/min
IS-B 0.00001 - 2500
IS-C 0.000001 - 250
IS-A 0.00001 - 500 inch
or
deg/rev
IS-B 0.000001 - 50
IS-C 0.0000001 - 5
mm inch
IS-A 0.001 - 250000 mm
or
deg/min
IS-B 0.0001-25000
IS-C 0.00001-2500
IS-A 0.0001 - 5000 mm
or
deg/rev
IS-B 0.00001-500
IS-C 0.000001-50
6.2.2 Clamping the Cutting Feed
The maximum programmable feed on a particular machine can be clamped (set as a parameter) by
the manufacturer of the machine. The value set there invariably refers to minutes. That value is also
the speed of DRY RUN. If a programmed feed higher than that is set, the control will clamp it