Mitsubishi Electronics Q03UD(E)CPU Sleep Apnea Machine User Manual


 
35
CHAPTER 3 SYSTEM CONFIGURATION
3
3.1 System Using Basic Model QCPU as CPU No.1
3.1.1 Available CPU modules, base units, power supply modules, and extension cables
(3) When a slim type main base unit (Q3SB) is used
(a) Available modules, the number of extension base units, and the number of
mountable modules
(b) Precautions
Slim type main base units do not have an extension cable connector. Therefore, no extension base unit or GOT
can be bus-connected.
Item Description
Number of CPU
modules
2 CPU modules
CPU No.1 (Basic model QCPU)
CPU No.2 (C Controller module)
Applicable CPU
module
*1
Basic model QCPU Q00CPU, Q01CPU Function version B or later
C Controller module
Q06CCPU-V, Q06CCPU-V-B,
Q12DCCPU-V
No function version restriction
Maximum number of
extension base units
Extension not allowed
Maximum number of
mountable I/O
modules
Q32SB 1
Q33SB 2
Q35SB 4
Applicable main base
unit
Q32SB, Q33SB, Q35SB
Applicable power
supply module
Q61SP