Jacuzzi U961000F Bathroom Aids User Manual


 
Electrical Connection 6060 With Heater
On the 6060 with integral skirt, one junction box has
been provided for the pump/motor and one for the heater.
To access, remove skirt access panel. See top view for
location.
A separate GFCI protected outlet (not provided) is re-
quired for pump/motor and is to be installed in the junc-
tion box. The junction box is to be hard wired. The
motor is bonded to the junction box at the factory.
Install a separate 120 VAC 15 AMP dedicated circuit
with GFCI protection. With a #8 solid copper wire, bond
the heater to the house electrical panel or approved lo-
cal bond. A bonding lug is provided on the heater.
At initial start-up and before each use thereafter with
power ON, push the GFCI test button. The reset button
should pop out. Push this button in to reset. If the inter-
rupter fails to operate in this manner, there is a ground
current flowing or a device malfunction, indicating the
possibility of electrical shock. Turn off power and do
not use the bath until the source of the problem has
been identified and corrected.
Electrical Connections
A separate circuit, which must be protected by a
Ground Fault Circuit Interrupter (GFCI), is required.
Install a duplex outlet to the studwall underneath the
bathtub, at least 4 inches above the floor. The duplex
outlet is not provided. Because these units are manu-
factured with a safe, convenient Magic Touch whirlpool
ON/OFF switch on the bath itself, no remote switch or
timer is necessary. If an optional timer is desired, one
is available from Jacuzzi Whirlpool Bath for 115 VAC
operation.
DANGER: RISK OF ELECTRIC SHOCK. Connect
only to a circuit protected by a Ground Fault Circuit
Interrupter.
CAUTION: Operating the motor/pump without
enough water in the bath can cause leaking and per-
manent damage to the pump. Before power is ap-
plied to the installation, make sure the switch is in
the OFF position to avoid pump damage.
ELECTRICAL CONNECTION
(FOR SIDE/END DRAIN BATHS)
DUPLEX
RECEPT.
*
3 PRONG
PLUG
4" MIN.
*(NOT PROVIDED)
FLOOR
INSTALLATION
ELECTRICAL CONNECTION
(FOR MOTOR PUMP ON DRAIN SIDE)
3 PRONG
PLUG
DUPLEX
RECEPT.*
*(NOT PROVIDED)
FLOOR
4" MIN.
OR IN
ACCORDANCE
WITH LOCAL
BUILDING OR
ELECTRICAL
CODES
GFCI
BONDING TO PUMP/MOTOR
POWER CORD
TO MOTOR
60x60 WITH INTEGRAL SKIRT
MOTOR JUNCTION BOX
GFCI
BONDING TO RAPIDHEAT
POWER CORD
TO RAPIDHEAT
60x60 WITH INTEGRAL SKIRT
RAPIDHEAT JUNCTION BOX
PUSH TO RESET
OVER HEAT
PROTECTION
HEATER ON
7
Jacuzzi Whirlpool Bath© U961000F 12/04