Honeywell Y8610U Oxygen Equipment User Manual


 
Y8610U INTERMITTENT PILOT RETROFIT KIT
3 68-0291—03
Transformer Sizing:
Add current ratings of Y8610, vent damper, and any other
control system components. Multiply this total by 24V to
determine the transformer VA requirement.
Mounting:
Mounts in any position except with terminals up. Recom-
mended mounting position is with terminals down to provide
maximum protection from dripping water or dust accumula-
tion. Refer to Fig. 14 on page 12.
Fasten with No. 6-32 machine screws or No. 8 sheet metal
screws or 8-18 x 5/8 pan head tapping screws of appropri-
ate length.
Wiring Connections:
Between the module and gas control: 30 in. (762 mm)
wiring harness with 1/4 in. quick-connect terminals.
Between the module and the igniter-sensor: 30 in.
(762 mm) ignition cable with stud terminal and 1/4 in.
quick-connect terminal.
Terminals:
1/4 in. male quick-connects. S8610U has Molex plug for
connection to a vent damper harness. Once the S8610U
has powered a vent damper, the module works only if the
vent damper is connected.
VR8204A and VR8304M Dual Valve
Combination Gas Controls
Specifications
Mounting:
Can be mounted from 0 to 90 degrees, in any direction,
from the gas control upright position
Pressure Rating: 1/2 psig (3.45 kPa) inlet pressure
Terminals: 1/4 in. male quick-connect terminals
Igniter-Sensor Specifications
Model:
392431 Igniter-Sensor; includes igniter-sensor assembly,
ground rod, and adapter (refer to Fig. 1 on page 4)
Electrode/Flame Rod Material: Kanthal
Maximum Temperature Ratings:
Ground Rod Tip: 1775°F (968°C)
Ceramic Insulator: 1250°F (677°C)
Dimensions: See Fig. 5 on page 6.
Mounting:
Attach the supplied ground rod and adapter, which replace
the thermocouple on the existing pilot burner
Table 2. VR8204A and VR8304M Dual Valve Combination Gas Controls Specifications.
Model Capacity
a
a
Based on 1,000 Btu/ft
3
, 0.64 specific gravity natural gas at 1 in. wc pressure drop (37.3 MJ/m
3
, 0.64 specific gravity natural gas at
0.25 kPa pressure drop).
Pipe Size Ambient Temperature Rating Dimensions
VR8204A
150 ft
3
/hr (4.2 m
3
/hr); (with or
without 1/2” x 3/4” adapter)
1/2 in. X. 1/2 in. NPT
inlet x outlet
b
b
3/4 in. straight flange included to provide 3/4” NPT outlet if needed.
0° to 175° F (-18° to 79° C) See Fig. 4 on page 5
VR8304M
270 ft
3
/hr (7.6 m
3
/hr)
1/2 in. X. 3/4 in. NPT
inlet x outlet
-40° to 175°F (-40° to 79°C) See Fig. 3 on page 5