Graham Field fr566g Wheelchair User Manual


 
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions 15
selector switch
Selector Switch (Mounted
Underneath Right Armrest)
Connection
The Heat and Massage Unit comes pre-installed
in Lumex Clinical Care Recliners with the Heat
and Massage Option (FR566GH and FR566DGH).
During recliner shipment, the Heat and Selector
Switch connections are disconnected. Several easy
connections are all that is required to make the unit
functional.
Main Components
1. The selector switch (shown at right), in the
switch box mounted on the right side of the
recliner underneath the armrest, is a single
multi-position switch that activates both the
Heat and Massage functions.
2. The control module, the
brains of the system, is
inside the junction box.
Both are shown at right.
3.
The power supply, which
has an 8-foot power cord
that plugs into the wall
power outlet, is shown at
right.
Control Module (Junction
Box Cover Removed)
Junction Box Power Supply