Graco 332089B Pill Reminder Device User Manual


 
Optional Cycle Detection Sensors
332089B 7
Optional Cycle Detection
Sensors
The sensors are magnetic reed switches and must be
connected to an electrical control package. The sensors
wires are #24 awg and have 9 foot (2.7 meters) flying
leads. An LED on the sensor illuminates to indicate a
change in state.
Suggested Sequence of Operation (See
page 16).
The Valve Inputs are listed in FIG. 9, page 22.
The Valve Outputs (supplied by others) consisting of
two power valves or one dual power valve [Sole-
noid-Close Spool Valve/RETract (Green Tube 1/4 in.
OD) and Solenoid-Open Spool Valve/EXTend (Yel-
low Tube 1/4 in.OD)]. Connect each Quick Discon-
nect (5/16-24 fitting) to respective power valve port.
Other needed Input would include some type of
Start device (Foot Switch or Control Box) (supplied
by others)
1. Home (Reload) Position
a. Solenoid-Close Spool Valve/RETract is acti-
vated.
b. Solenoid-Open Spool Valve/EXTend is deacti-
vated.
c. PX-EXT and PX-CSV signal have been made.
d. PX-RET and PX-OSV signal is not made.
e. Metering Rod is Retracted.
2. Shot Procedure
a. Start device signal is made.
b. Solenoid-Close Spool Valve/RETract is deacti-
vated.
c. Solenoid-Open Spool Valve/EXTend is acti-
vated.
d. PX-EXT and PX-CSV signal drops off.
e. Spool shifts from the Reload Position to the Dis-
pense Position.
f. PX-OSV signal is made.
g. Metering Rod Extends downward (Dispensing
Material).
h. PX-RET signal is made and Metering Rod is
down (Dispense Material Complete).
i. Solenoid-Open Spool Valve/EXTend is deacti-
vated.
j. Solenoid-Close Spool Valve/RETract is acti-
vated.
k. PX-OSV signal drops Spool shifts from the Dis-
pense Position to the Reload Position and
Metering Rod Retracts upward (Reloading
Material).
l. PX-CSV signal is made.
m. PX-EXT signal is made.
n. Dispense Valve is ready for next Start device
signal.