Grounding
6 332089B
Grounding
This product must be grounded. In the event of an elec-
trical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric cur-
rent.
Metering valve: attach ground wire from grounding lug
to true earth ground. See Component Identification
starting on page 8.
Fluid hoses: use only electrically conductive hoses.
Feed system components: attach ground wire from
grounding lug to true earth ground. See feed system
manual for grounding points.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
Overview
This single-component meter and dispense device
accurately meters liquid and semi-paste materials.
The machine is ideal for a single-component application
requiring very small and precise shots.
The ratio of the pneumatic cylinder area to pump shaft
area provides the adjustable pressure intensification
needed to move the liquids through the needle with a
flow rate suitable for production requirements.
The complete system is enclosed. See Sequence of
Operation on page 16.