Golden Technologies GP215 Wheelchair User Manual


 
Alante DX/LT Owner’s Manual Rev A_011811
VII. OPERATION
DIAGNOSTICS/TROUBLESHOOTING
Below is a list of trouble-shooting actions. Try to use this list before you contact your
Golden Technologies representative. Go to the number on the list which matches the
number of flashing LEDs and follow the instructions. If the problem persists after you
made the checks described, contact your Golden Technologies representative for further
assistance.
1 LED The battery needs charging or there is a bad connection to the battery. Check
the connections to the battery. If the connections are good, try charging the battery.
2 LEDs The left hand motor has a bad connection. Check the connections to the left hand
motor.
3 LEDs The left hand motor has a short circuit to a battery connection. Contact your
Golden Technologies representative.
4 LEDs
T
he right hand motor has a bad connection. Check the connections to the right
hand module.
5 LEDs The right hand motor has a short circuit to a battery connection. Contact your
Golden Technologies representative.
6 LEDs
T
he wheelchair is being prevented from driving by an external signal. The exact
cause will depend on the type of wheelchair you have, one possibility is the battery charger
is connected.
7 LEDs A
j
oystick fault is indicated. Make sure that the
j
oystick is in the center position
before switching on the control system.
8 LEDs A control system fault is indicated. Make sure that all connections are secure.
9 LEDs The parking brakes have a bad connection. Check the parking brake and motor
connections. Make sure the control system connections are secure.
10 LEDs An excessive voltage has been applied to the control system. This is usually
caused by a poor battery connection. Check the battery connections.
29