Field Controls FC95HRV. Oxygen Equipment User Manual


 
Your HRV/ERV system produces a dehumidifying effect when
outdoor humidity levels are lower than indoor humidity levels.
These conditions occur normally when outdoor termperatures are
below 60°F. An additional dehumidification effect is achievable
with the Optional Dehumidistat (Part DH1).
The Optional DH1 Control may be combined with the Healthy
Home System Control (HHSC). The DH1 will initiate high speed
ventilation when the moisture level in the home exceeds the set
point on the control. Once the humidity in the house is reduced,
the HRV will revert back to the HHSC automatic setting. The
Dehumidistat should be set to OFF for all seasons except the
heating season.
Dehumidistat (Part DH1)
Healthy Home System Control (HHSC)


Dehumidistat Indicator
LEDs
Set to the desired humidity
level. High speed ventilation
will initiate when the indoor
moisture level exceeds the set
point on the control.
Dehumidistat
Adjust button
The Healthy Home System Control (HHSC) activates the
HRV/ERV automatically to deliver fresh air into your home.
Setting the Control
The duration of the ventilation rate is adjustable on the HHSC.
Your installer sets up this control during the installation of your
system . Refer to the instructions that came with the HHSC for the
setup information.
The Healthy Home System™ Control (HHSC)
4