Field Controls FC95HRV. Oxygen Equipment User Manual


 
Installation
STEP 4. Level the unit from left to right and front to back.
- Adjust the unit down by lifting up on the buckle.
- Adjust the unit up by pulling down vertically on the Hand
Loops while lifting up the bottom of the cabinet.
Location
Install the unit in a heated space that provides convenient space for
service access. A typical location is in either a mechanical room or
an area close to the outside wall within close proximity to where
the weatherhoods are mounted. If a basement area is inconvenient
or non- existent, install the unit in a utility or laundry room.
Attic installations are not recommended due to:
A) the complexity of work to install
B) freezing conditions in the attic
C) difficulty of access for servicing and cleaning
Leave sufficient clearance at the front of the access door for
servicing the air filters and core. The recommended clearance is a
minimum of 25" (635 mm) for opening and closing the door. Field
Controls provides four straps for hanging the unit from the
basement floor joists.
Hand Loops
Buckles
Pull down on the hand
loops while lifting
the bottom of the unit.
I
mproper installation, adjustment, alteration,
service or maintenance can cause property
damage, personal injury or loss of life.
Installation and service must be performed by
a qualified installer or service agency.
WARNING
Unit must be installed level to ensure proper
condensate drainage. Due to the broad range of
installation and operational conditions, consider
the possibility of condensation forming on either
the unit or connecting ducting. Objects below the
installation may be exposed to condensate.
CAUTION
Hand Loops
Screws (not included)
Buckles
Joist
Washers (not included)
Hanging Strap grommets
“S” hooks
Note:This illustration of the unit may
vary from the unit you are installing.
DETAIL
Suspend the Unit with the Adjustable Hanging Straps
STEP 1. Insert the screws and washers (not included) through
the Hanging Strap grommets and fasten to the joists.
STEP 2. Unscrew the 4 machine screws located on the upper
side of the unit. Attach the "S" hooks and reinsert the machine
screws.
STEP 3. Hook the bottom grommets of the straps through the "S"
hooks. Pull down vertically on the hand loops while lifting up the
bottom of the cabinet. Repeat at opposite end of the unit.
Hand Loops
Straps
STEP 5. Fold the hand loops and excess strap and secure with a
nylon tie (not included).
Use 4 screws and 4 washers (not incldued) to attach the hanging
straps to the floor joists. The washer must be wider than the eyelet
of the grommet on the hanging strap.
By design, the adjustable hanging straps reduce the possibility of
noise, resonance, and harmonics.
Note: Do not pull the
Hand Loops in a
horizontal or lateral
direction during the
installation/adjustment
process.
17