Outdoors
Installation Notes
Unit is normally balanced on HIGH speed with the furnace blower ON.
Weatherhood arrangement is for drawing purposes only. Six feet (2m) minimum separation
is recommended. The Weatherhood must also be 18" (460mm) above grade minimum.
The airflow must be confirmed on site using the balancing procedures found in this manual.
Dampers for
balancing
airflows
Stale air from various
parts of home.
i.e. bathrooms (if required)
Kitchens (if required)
Fresh air to house -
main living areas.
bedrooms, livingroom,
rec.room, etc.
Fully Dedicated Installation Diagrams
Fully Dedicated System
This is a stand alone HRV/ERV system which
is not connected to a force air system. Stale air
is drawn from key areas of the home (bathroom,
kitchen) while fresh air is supplied to main
living areas.
Key Points
The HRV/ERV must be balanced.
The duct configuration may change
depending on the HRV/ERV model. See
specifications for your unit.
Check local codes / authority having
jurisdiction for acceptance.