Excell Precision Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
42
5-7 BAUD RATE SETTING
ΠPress the
Z
key until the unit weight displays then press
1
WEIGHT UNIT WEIGHT QUANTITY
- - - - -
- - - - - -
WEIGHT UNIT WEIGHT QUANTITY
Press the
7
key.
WEIGHT UNIT WEIGHT QUANTITY
X
Use number keys 0 to 3 key to select
0 1200
1 2400
2 4800
3 9600
Once the setting is done, re-start the scale by turning the power off / on.
Press the . key to exit the setting mode and the scale will return to counting mode.