Excell Precision Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
21
CHAPTER 3 USER INTERFACE SETTING
3-1 M+ KEY ACTION
Press Z then 1 twice.
Weight Unit Weight Quantity
X
Press 0 , 1 or 2 to select the required mode
0 = When M+ key is pressed, the display will show the totalised value. Then, the
scale will count back to zero after 3 seconds.
1 = When M+ key is pressed, the display will show the totalised value. Then, the
scale will count back to zero when the CE key is pressed.
2 = When M+ key is pressed, the beeper only will sound and the display won t
show the totalised value.
To exit and save the entry, press the key
3-2 PRE-SET TARE
Press Z then 1 followed by 2
Weight Unit Weight Quantity
X
Press 0 or 1 to select the required mode
0 = Pre-set Tare function is not available when there is an object on the scale.
1 = Pre-set Tare function is available when there is an object on the scale.
To exit and save the entry, press the key