Excell Precision Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
34
4-4-3 Quantity Preset
The scale can store a Hi Limit quantity value. The scale will make a warning beep
and the unit weight window will display a blinking . if the quantity is
over the Hi limit alarm value set.
Set the Hi Limit Value for Quantity Preset
ΠPress
QTY PST
key whether the scale has object on the weigh pan or not.
0
3
Stable
3
Latest Preset Value
Enter a desired Hi Limit value. Use
CE
key to correct the value entered.
0
3
Stable
3
Hi Limit Value Entered
Ž Press
SMPL
key. Use
CE
key to correct the value entered.
0
3
Stable
3
Press
QTY PST
key, the scale will return to counting mode.
0
3
.
Stable
3