Excell Precision Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
15
T
Press the
UNIT W.T.
key, the count is shown on the quantity display.
0
3
.
.
Stable
3
Unit Weight
The larger the sample weight is, the more accurate the count will be.
With both the Unit weight and Quantity displays showing zero, pressing either
the
UNIT W.T.
key or the
SMPL
key will recall the latest piece weight value.
2-9 DEDUCTION OF CONTAINER WEIGHT
2-9-1 The Weight of Container is Unknown ( Tare )
Œ Place the container onto the scale.
.
Container Weight
Press
T
Key.
Ž Once the scale stabilizes, it will display the net weight and the 3 icon next to
the NET symbol will be displayed.
0
3
3
.
Stable
3
2-9-2 Clear Tare Value
When the container is removed from the scale, the weight display will show a
negative sign. Press the
T
key again to clear tare value and the weight
display will reset to zero, the 3 icon adjacent to the NET symbol will go off.