Excell Precision Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
26
CHAPTER 4 KEYBOARD TYPES
4-1 STANDARD TYPE
4-1-1 Quantity Preset
The scale can store a Hi Limit quantity value. The scale will make a warning beep
and the unit weight window will display a blinking . if the quantity is
over the Hi limit alarm value set.
Set the Hi Limit alarm value for Quantity Preset
Method 1 :
Place the sample object onto the weigh pan and increase the number of
items gradually until the quantity reaches the desired Hi Limit alarm level.
Press
QTY PST
key to store this quantity preset alarm value.
Method 2 :
Enter directly the Hi Limit quantity number using the keypad, then press
the
QTY PST
key to store the value.
Clear the Hi Limit quantity value
To clear Hi Limit quantity value, press the
PST CE
key.