Dell 210S Microscope & Magnifier User Manual


 
7-6 Dell PowerVault 200S, 201S, 210S, and 211S Storage Systems Installation and Service Guide
c. Replace the SCSI backplane board.
Before replacing the SCSI backplane board, consider obtaining technical
assistance to see if other checks should be performed.
Is the problem resolved?
Yes. End troubleshooting.
No. See Chapter 8, "Getting Help," for instructions on obtaining technical
assistance.
7URXEOHVKRRWLQJD&RROLQJ)DQ
A redundant storage system contains three cooling fans, and a nonredundant storage
system contains two cooling fans. If the amber cooling fan fault indicator lights
up (see Figure 7-1) or the HP OpenView NNM SE x.x and the Dell OpenManage
HIP x.x server management programs issue a fan-related error message, replace the
fan as described in "Replacing a Cooling Fan," found later in this chapter.
)LJXUH&RROLQJ)DQVIRU3RZHU9DXOW[[66WRUDJH6\VWHPV
1 Fan fault indicator
2 Captive screws