Citizen CT503 Scale User Manual


 
4
Application Programs
Counting
Purpose
With the Counting program you can determine the number
of parts that each have approximately equal weight.
Available Features
Store the current weight value to have it loaded as the
preset reference sample quantity next time you initialize
the Counting application
The reference sample quantity can be changed in the
operating menu: See “Configuring the Scale”
The average piece weight is automatically output via the
optional data interface port after initialization, if the menu
code for “Printout with data ID codes” is set
Press [FUNCTION] to toggle the display between piece
count and weight
Factory Settings
Reference sample quantity: 10 (menu code 3. 3. 2)
Preparation
l Configure the Counting application in the
operating menu:
See “Configuring the Scale”
Menu code 2. 1. 4 Counting
l Reference sample quantity:
Menu code 3. 3. 1 5 pcs
Menu code 3. 3. 2 10 pcs
Menu code 3. 3. 3 20 pcs
Menu code 3. 3. 4 50 pcs
Menu code 3. 3. 5 100 pcs
See also “Configuring the Scale”
Example
Determine an unknown piece count; weigh the preset
reference sample quantity
Settings (changes in the factory settings required for
this example):
Menu: Application program: Counting (2 .1. 4)
Reference sample quantity: 20 pcs (3. 3. 3)
Step Key (or instruction) Display
1. Turn on the scale [ON/OFF]
2. Tare the scale t 0.000 ct
3. Display the reference [FUNCTION] ref 20 (briefly)
sample quantity > 2 sec.
(here: 20 pcs)
4. Place the reference + 16.000 ct
sample quantity
(20 pcs) on the
scale (here: 16 ct)
5. Start the application; [FUNCTION] + 20 pcs
if the print format is set
to include data ID codes,
the following is printed wRef + 0.8000 ct
6. Weigh uncounted parts + 174 pcs
(here: 174 pcs)
7. Display weight [FUNCTION] +139.200 ct
8. Display quantity [FUNCTION] + 174 pcs
9. Unload the scale 0 pcs
10. Delete the reference
value [CAL/CF] > 2 sec.
11. Repeat the procedure
starting from Step 6,
if desired.
Weighing in Percent
Purpose
This application program allows you to obtain weight
readouts in percent which are in proportion to a reference
weight.
Available Features
Store the current weight value to have it loaded as the
preset reference percentage next time you initialize the
Weighing in Percent application
The reference percentage can be changed
in the operating menu: See “Configuring the Scale”
The reference percentage is automatically
output via the optional data interface port after
initialization, if the menu code for “Printout
with data ID codes” is set
Press [FUNCTION] to toggle the display between
percentage and weight
Factory Settings
Reference percentage: 10 (menu code 3. 3. 2)