MAINTENANCE
Wear disposable vinyl gloves.1.
Unplug the Control Box line cord from 2.
the electrical outlet.
Discharge the Conducting Pole (9) to 3.
the Ground Clip (10).
Disconnect the air hose from the 4.
Spray Gun.
Remove the Cup and pour any re-5.
maining powder back into it’s original
container.
WARNING: Powder clouds/mist are
explosive. Before cleaning, remove
any possible ignition source in the
area .
Using compressed air, blow out the 6.
Cup and all other parts that have col-
lected powder.
Uncontaminated powder residue can 7.
be stored and reused.
Store powder and Powder Coating 8.
System in a box located in a clean
and dry location.
PARTS LIST
Item Description Qty
1 Control Box 1
2 Spray Gun 1
3 Spray Gun Pipe 1
4 Cup* 1
5 Air Outlet Pipe 1
6 Air Input Pipe 1
7 Trigger 1
8
Disposable Moisture Separator
(reorder item #42980)
1
9 Conducting Pole 1
10 Ground Clip 1
11 Pedal Switch 1
12 Scatter Tip 1
13 Emitter 1
14 Regulating Screw 1
15 Power Indicator Light 1
16 Running Indicator Light 1
17 Power Switch 1
18 Pressure Reducer Valve 1
19 Hose Adapter 1
*Note: Replacement cups provided for other powder coating systems (such as SKU
93306, 94646, or 94244) may not seal properly. Only use the cups provided.
Note: Some parts are listed and shown for illustration purposes only and are not avail-
able individually as replacement parts.