Adcom A723 Mobility Aid User Manual


 
CHAPTER 4
Using terminal commands
33
APPLIES TO A720, A720B, A723
DESCRIPTION Sets/returns the input storing and sampling intervals.
PARAMETERS storage represents the time (in seconds) elapsed between two
slots stored in the internal memory, while samples represents the
numbers of samples used to build the average that will be stored.
RETURNS The interval and rate.
REMARKS The default storage is 900 (15 minutes) and samples is 3 (3 sam-
ples per quarter of an hour).
REMOTE Yes, SET only.
EXAMPLE SLOT 900 3
193 SLOT 0
#
SLOT
193 SLOT 900 3 0
#
Note: The A720B base station needs only the rate. For consis-
tency, however, it accepts both parameters and discards the
one it doesn’t need.
COMMAND PMP
APPLIES TO A720, A720B, A723
DESCRIPTION Sets/returns the node’s Power Management Parameters (switches
on/off the battery charge).
PARAMETERS The lower (switch on) and the higher limit (switch off), both in volts
x 10. Standard Values are 65 (for 6.5 Volts) for switch on and 72 (for
7.2 Volts) for switch off.
RETURNS The lower (switch off) and the higher limit (switch on), both in volts
x 10.
REMARKS GET/SET.
REMOTE Yes, SET only.
EXAMPLE PMP 65 72
193 PMP 0
#