CHAPTER 4
Using terminal commands
27
EXAMPLE SET OWNID 2003
COMMAND SET PMP bl bh
DESCRIPTION Sets the power management parameters.
PARAMETERS bl is the lower battery level (the threshold where the charging of
the battery is switched on) and bh is the higher battery level (the
charging is switched off).
RETURNS Nothing.
REMARKS Both bl and bh are expressed in volts X 10 (for example, 72 actually
means 7.2 V). Default values (factory programmed) are 65 and 72,
meaning 6.5 and 7.2 volts respectively.
EXAMPLE To change the switch-on threshold to 6.3 and the switch-off thresh-
old to 7.0 volts:
SET PMP 63 70
COMMAND SET SLOT storage samples
DESCRIPTION Configures the input sampling and storing intervals.
PARAMETERS storage represents the time (in seconds) elapsed between two
slots stored in the internal memory, while samples represents the
numbers of samples used to build the average that will be stored.
RETURNS Nothing.
REMARKS The default storage is 900 (15 minutes) and samples is 3 (3 sam-
ples per quarter of an hour).
EXAMPLE To sample the inputs (sensors) every minute and build an hourly
average:
SET SLOT 3600 60
To sample the inputs once per hour and store the values as they
are:
SET SLOT 3600 1