A&D UA-1030TCN Blood Glucose Meter User Manual


 
E-15
A&D Medical (Toll-Free): 1-888-726-9966
E-16
In Canada - Auto Control Medical (Toll-Free): 1-800-461-0991
MEASUREMENT WITH SET PRESSURE WHAT IS AN IRREGULAR HEARTBEAT
The UA-1030T is designed to detect the pulse and to inflate the cuff to a systolic
pressure level automatically. If re-inflation occurs repeatedly, use the following
methods.
During the blood pressure measurement, re-inflation may occur. A fixed pressure
value can be set to avoid re-inflation.
1. At step 6 of the clock adjustment procedure (see page
E-10), press the
SET
button to go to the pressure setting
mode. The current setting blinks.
2. Press the or button to select a pressure value
about 30 mmHg or more above your expected systolic
pressure from the following.
AUTO
: Automatic pressurization (default value)
180
: Pressure value of 180 mmHg (fixed)
210
: Pressure value of 210 mmHg (fixed)
240
: Pressure value of 240 mmHg (fixed)
3. Press the
SET
button to go to the TriCheck setting mode.
Press the
START
button to turn the device off. After three minutes of
non-operation, the device will turn off automatically. The next measurement
will be performed with the new pressure value.
Turn off
TriCheck
setting mode
or
START
Refer to previous page
for measurement
Press and hold the button
At heart level
Release the button
at the desired
systolic pressure
MEASUREMENT WITH DESIRED SYSTOLIC PRESSURE
Use this method when re-inflation occurs repeatedly even if the pressure value is
set to
240
in the procedure above or when the results are not displayed even if
the pressure decreases to 20 mmHg or less.
1. Place the cuff on the arm (preferably the left arm).
2. Press and hold the
START
button until a number
about 30 to 40 mmHg higher than your expected
systolic pressure appears.
3. When the desired number is reached, release the
START
button to start measurement. Continue to
measure your blood pressure as described on the
previous page.
Turn off
TriCheck
setting mode
or
START
Refer to previous page
for measurement
Press and hold the button
At heart level
Release the button
at the desired
systolic pressure
The UA-1030T blood pressure monitor provides a blood pressure and pulse rate
measurement even when an irregular heartbeat occurs. The Irregular Heartbeat
symbol
123
123
123
123
123
123
123
123
123
123
123
123
err CUf
p-3
1932-1AIc UA787EXC•06 illust•03,12p symbols.FH7
will appear in the display window in the event an Irregular
Heartbeat has occured during measurement. An irregular heartbeat is defined as
a heartbeat that varies by 25% from the average of all heartbeat intervals during
the blood pressure measurement. It is important that you relax, remain still and
refrain from talking during measurements.
Note: We recommend contacting your physician if you see this symbol frequently.
ABOUT CUFF INFLATION METER
The Cuff Inflation Meter is located on the left side of the display screen to tell
you when the blood pressure monitor is inflating and deflating the cuff. The Cuff
Inflation Meter moves up during inflation and moves down during deflation.
Inflation in Progress Inflation Complete
Deflation/Measurement
in Progress