HV-WP/HW-WP Series Page 35
12. Full/Dribble Batch Function
Step 8 Press the MODE switch to display the blinking HI (of
the final value).
Step 9 Set the final value using the following switches.
∧ switch Selecting the number of a figure.
< switch Selecting a figure.
Step10 Press the ENTER switch to store the new parameter
and display the blinking OK (of preliminary value).
Step 11 Set the preliminary value using the following switches.
∧ switch Selecting the number of a figure.
< switch Selecting a figure.
Step12 Press the ENTER switch to store the new parameter
and display the blinking LO (of zero band).
Step13 Set a zero band which is greater than the tare value,
using the following switches.
∧ switch Selecting the number of a figure.
< switch Selecting a figure.
Step14 Press the ENTER switch to store the new parameter
and display the weighing mode.