11. Upper/Lower Comparator Function
11.2.
11.2.11.2.
11.2. Operation and Performance (Examples)
Operation and Performance (Examples)Operation and Performance (Examples)
Operation and Performance (Examples)
Example 1
This example is set as follows:
Function table f6 3 (If the current display value is not nearly-zero,
the scale compares the display value with the
upper limit value and the lower limit value
immediately.)
Upper limit value (HI) 7.000kg
Lower limit value (LO) 6.500kg
Case
The comparison starts at turning the scale on.
When the current value is less than 6.500kg, LO is displayed.
When the current value is 6.500kg to 7.000kg, OK is displayed.
When the current value is greater than 7.000kg, HI is displayed.
Example 2
This example is set as follows:
Function table f6 4 (Pressing the SET switch, after the stability
mark is displayed, the scale compares the
current display value with the upper limit value
and the lower limit value immediately.)
Upper limit value (HI) 2.000kg
Lower limit value (LO) -1.000kg
Case
Pressing the SET switch, the comparison is performed after displaying the stability
mark.
When the current value is less than -1.000kg, LO is displayed.
When the current value is -1.000kg to 2.000kg, OK is displayed.
When the current value is greater than 2.000kg, HI is displayed.