F35 CALIBRATION REQUEST
Used in distance control RS485
F36 CALIBRATING IN PROGRESS
Used in distance control RS485 to know when calibrating end.
F38 THE MACHINE IS WAITING A COOLING DOWN DURING A CALIBRATION PROCEDURE
Wait please
F46 NO CURRENT SIGNAL
Verify sealing band connection,TA connection
F47 TA SIGNAL WRONG TURNED
TurnTA connection
F48 PRE-HEATING POTENZIOMETER NO CONNECTED OR CABLES BROKEN
Verify pre-heating potenziometer connections and cables
F49 SEALING POTENZIOMETER NO CONNECTED OR CABLES BROKEN
Verify sealing potenziometer connections and cables
F51 WIPER-I
Switch off and switch on the thermoregulator; if problem persist call the supplying
F52 WIPER-V
Switch off and switch on the thermoregulator; if problem persist call the supplying
F53 WIPER-VGROSS
Switch off and switch on the thermoregulator; if problem persist call the supplying
F54 WIPER-VFINE
Switch off and switch on the thermoregulator; if problem persist call the supplying
F60 RESET WITH CALIBRATING IN PROCESS
Repeat the calibrating
F61 BALANCE UNSUCCESSFULL
Repeat the calibrating
F62 BALANCE V UNSUCCESSFULL
Repeat the calibrating
F63 BALANCE VGROSS UNSUCCESSFULL
Repeat the calibrating
F64 BALANCE VFINE UNSUCCESSFULL
Repeat the calibrating
F65 BALANCE UNSUCCESSFULL
Repeat the calibrating
F66 MAIN PHASE SYNCHRONISM
Reset the thermoregulator if problem persist call the supplying
F69 CURRENT TO GROUND
Verify sealing bands in the machine touch ground.
F71 FAULT HARDWARE –15V INTERNAL
Reset the thermoregulator; if problem persist call the supplying
F72 FAULT HARDWARE +15V INTERNAL
Reset the thermoregulator; if problem persist call the supplying
F73 FAULT HARDWARE +5V INTERNAL REFERENCE
Reset the thermoregulator; if problem persist call the supplying
F76 IREAD TOO HIGH
Verify if short circuit on the seals
F78 THERMOREGULATOR NOT CALIBRATED
Do a calibrating
F79 FAULT OF EMERGENCY CIRCUIT
Verify contactor power, verify emergency chain