THERMOSALD ISC – MANUAL QUICK START Rev. 2005 / 03
Manual cod.: 3ES080x_Vx_QS_EN Page Nr. 17 Tot. Nr . 17
4.9 - SETUP PROCEDURES WITH THE AID OF THE CONTROL PANEL
1) Enter the theoretical values (see paragraph 4.8 above)
2) Access the DIAGNOSTIC ANALYSIS submenu (see paragraph 4.8 above)
3) Read the effective pulsed voltage of the strip, THEORETICAL V.
4) Set the transformer secondary voltage allowing for a multiplication coefficient of 1.5 2 for pulsed operation and a
coefficient of 1 1.5 for continuous operation:
transformer V = strip V x multiplication coefficient (1 1.5 - 2), select the nearest one.
4.10 - SETUP PROCEDURES WITHOUT USING THE CONTROL PANEL MANUAL MODE
Calculating total resistance:
R strip=specific resistance[Ohm/m] x strip length[m]
Calculating the strip cross-section S:
Strip cross-section S[mm
2
]=strip length[mm] x strip thickness[mm]
Calculating the theoretical pulsed heating currents I:
I heating=strip cross-section S[mm
2
] x 30[Amp/ mm
2
]
Calculating the effective pulsed voltage applied to the strip:
V strip=R strip x I heating
Calculating the transformer secondary voltage allowing for a multiplication coefficient of 1.5 2 to increase the sealing
speed under pulsed operating conditions and coefficient 1 for continuous operation:
V transformer= V strip x multiplication coefficient (1 1.5 - 2)
(select the nearest one)