A SERVICE OF

logo

Maintenance
6-2
Part 7119745C
E 2007 Nordson Corporation
MiniCure 08-07
Lamp installation & removal
Ensure the system is completely cool, this takes typically about 2 mins with
the fan running.
Ensure the ’System Isolator’ is in the OFF position.
Remove the hood assembly by lifting evenly from the front and back.
Remove the black reflector box assembly to expose the lamp brackets.
FIG. NUV3A
1
2
3
4
6
5
Figure 6-2
1. Hood
2. Reflector Box
3. Lamp Bracket
4. Connector Lamp Lead
5. 4 x Cross Head Screws
6. Retaining Clip
Release the two lamp retaining clips from the lamp brackets by undoing the
four steel crosshead screws.
Fit the lamp into the lamp brackets avoiding touching the lamp’s glass
surface. If the lamp’s surface does get contaminated, it should be cleaned
with an alcohol based solvent that does not contain oils (e.g. isopropanol
alcohol).