Installation 4-1
Part 7119745C
E 2007 Nordson Corporation
MiniCure 08-07
Section 4
Installation
W ARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
Fig NUV2A
1
3
42
Figure 4-1
1. Emergency Stop
2. Outlet Shield
3. System Isolator 4. Substrate Collection Tray
In certain circumstances the lamp may be packed separately for transit.
Please see the maintenance section ’Lamp Installation and Removal’ for
directions on how to fit the lamp.
The MiniCure must be professionally connected into a 3--phase + Neutral
supply. This must be capable of supplying the Voltage, Frequency and
Amperage specified on the rating plate of the unit (this is located on the
front of the unit).
The electrical supply to the machine needs to be connected to the 1.5m
connection cable that exits at the right hand side, next to the ’System
Isolator’.
Connect the live supply cables (L
1
,L
2
,L
3
,) and the Neutral cable (N) into a
suitable fixed wall supply box.
The earth cable (PE) must also be connected.