A SERVICE OF

logo

4-15
MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide
PRELIMINARY
Command/response table for SIS commands (continued)
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Information requests (continued)
Query controller fi rmware
version (verbose)
0Q
X1(
-
X2)
-
X2)]
Provide a detailed status
of the Ethernet protocol
rmware, the controller
rmware, and any fi rmware
upgrade. The fi rmware that
is running is marked by
an asterisk (*). A caret (^)
indicates that the fi rmware
has a bad checksum or an
invalid load. ?.?? indicates
that fi rmware is not loaded.
Response description:
Ethernet protocol fi rmware version-controller fi rmware version-updated fi rmware version
]
Example:
0q
Ethernet protocol
firmware
Response:
Description
CrossPoint/MAV firmware version
1.23-0.14(0.20-32x32 Series - , 00 2000 00:00:00 GMT)-0.25*(0.24-32x32 Series -Thu, 20 Mar 2003 16:39:21 GMT)
Updated firmware version
* indicates the version running Upload date and time
Request system status S
X2$•X2$•X2$•X2$•X2$•X2%]
Response description:
+3.3V
+5V
-5V
+15V
-15V
temperature (degrees fahrenheit)
]
Example:
3.29•5.04•-5.14•15.27•-15.15•120.20
-15V power system at -15.15V
Temperature 120.20 degrees3.3V power system at 3.29V