![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/8e/f8e22909-6b84-49d6-b257-d579d772f566/f8e22909-6b84-49d6-b257-d579d772f566-bg8c.png)
Change the Output Volume Level
The output volume attenuates the signal from full volume down to 0 volume in 100 steps.
Users can set individual output volume levels from a range of –100dB (full attenuation,
minimum volume) to 0dB (no attenuation, full volume).
Change an output audio level setting as follows:
1. Next to the desired output number, click the output level drop-down box. A
drop-down list box appears.
2. Click and drag the slider or click the scroll up button or scroll down button until
the desired audio level is visible.
Alternately the + and - boxes increment the level up or down one step.
3. Click the desired attenuation value. The range is –100 to 0dB.
4. Repeat steps 1 through 3 for each output.
Group Controls Page
If group controls have been set using SIS commands or DSP Configurator, the group
controls page provides access to those controls (see figure 73). Group controls cannot
be set using the HTML pages. Access the group controls page by clicking the Group
Controls link on the left of the control page.
Figure 73. Group Controls Page
To adjust a group control:
• Next to the desired group control, directly input a value by clicking in the box and
typing a value, or use the + and – box to increment or decrement the value by one.
• Repeat for each group.
NOTE: The range of each group control is displayed under the value box.
DMP64 • HTML Operation 134