4 – OPERATOR SERVICE
41
Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
055 OPEN CIRCUIT
RF OUTRIGGER
The Lower Control has detected an open circuit on the
RF Outrigger solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty RF Outrigger solenoid wiring
2. Faulty RF Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace RF Outrigger solenoid
wiring
2. Replace RF Outrigger solenoid
3. Replace Lower Control
056 SHORTED CIRCUIT
RF OUTRIGGER
The Lower Control has detected excessive current on
the RF Outrigger solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty RF Outrigger solenoid wiring
2. Faulty RF Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace RF Outrigger solenoid
wiring
2. Replace RF Outrigger solenoid
3. Replace Lower Control
057 OPEN CIRCUIT
LR OUTRIGGER
The Lower Control has detected an open circuit on the
LR Outrigger solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty LR Outrigger solenoid wiring
2. Faulty LR Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace LR Outrigger solenoid
wiring
2. Replace LR Outrigger solenoid
3. Replace Lower Control
058 SHORTED CIRCUIT
LR OUTRIGGER
The Lower Control has detected excessive current on
the LR Outrigger solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty LR Outrigger solenoid wiring
2. Faulty LR Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace LR Outrigger solenoid
wiring
2. Replace LR Outrigger solenoid
3. Replace Lower Control
059 OPEN CIRCUIT
RR OUTRIGGER
The Lower Control has detected an open circuit on the
RR Outrigger solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty RR Outrigger solenoid wiring
2. Faulty RR Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace RR Outrigger solenoid
wiring
2. Replace RR Outrigger solenoid
3. Replace Lower Control
060 SHORTED CIRCUIT
RR OUTRIGGER
The Lower Control has detected excessive current on
the RR Outrigger solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty RR Outrigger solenoid wiring
2. Faulty RR Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace RR Outrigger solenoid
wiring
2. Replace RR Outrigger solenoid
3. Replace Lower Control