40
Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
049 OPEN CIRCUIT
OUTRIGGER RETRACT
The Lower Control has detected an open circuit on
the Outrigger Retract solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as
an open circuit. The typical load is approximately
800mA.
Possible causes include:
1. Faulty Outrigger Retract solenoid wiring
2. Faulty Outrigger Retract solenoid
3. Faulty Lower Control
1. Repair or replace Outrigger Retract solenoid
wiring
2. Replace Outrigger Retract solenoid
3. Replace Lower Control
050 SHORTED CIRCUIT
OUTRIGGER RETRACT
The Lower Control has detected excessive current on
the Outrigger Retract solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Outrigger Retract solenoid wiring
2. Faulty Outrigger Retract solenoid
3. Faulty Lower Control
1. Repair or replace Outrigger Retract solenoid
wiring
2. Replace Outrigger Retract solenoid
3. Replace Lower Control
051 OPEN CIRCUIT
OUTRIGGER EXTEND
The Lower Control has detected an open circuit on
the Outrigger Extend solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as
an open circuit. The typical load is approximately
800mA.
Possible causes include:
1. Faulty Outrigger Extend solenoid wiring
2. Faulty Outrigger Extend solenoid
3. Faulty Lower Control
1. Repair or replace Outrigger Extend solenoid
wiring
2. Replace Outrigger Extend solenoid
3. Replace Lower Control
052 SHORTED CIRCUIT
OUTRIGGER EXTEND
The Lower Control has detected excessive current on
the Outrigger Extend solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Outrigger Extend solenoid wiring
2. Faulty Outrigger Extend solenoid
3. Faulty Lower Control
1. Repair or replace Outrigger Extend solenoid
wiring
2. Replace Outrigger Extend solenoid
3. Replace Lower Control
053 OPEN CIRCUIT
LF OUTRIGGER
The Lower Control has detected an open circuit on
the LF Outrigger solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as
an open circuit. The typical load is approximately
800mA.
Possible causes include:
1. Faulty LF Outrigger solenoid wiring
2. Faulty LF Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace LF Outrigger solenoid
wiring
2. Replace LF Outrigger solenoid
3. Replace Lower Control
054 SHORTED CIRCUIT
LF OUTRIGGER
The Lower Control has detected excessive current on
the LF Outrigger solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty LF Outrigger solenoid wiring
2. Faulty LF Outrigger solenoid
3. Faulty Lower Control
1. Repair or replace LF Outrigger solenoid
wiring
2. Replace LF Outrigger solenoid
3. Replace Lower Control