BIL-JAX 2622T
38
Error Message
Displayed
Error Explanation &
Possible Causes
What To Check &
Corrective Action To Clear
Error
037 OPEN CIRCUIT
PLATFORM LEVEL UP
The Lower Control has detected an open circuit on the
Platform Level Up solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Platform Level Up solenoid wiring
2. Faulty Platform Level Up solenoid
3. Faulty Lower Control
1. Repair or replace Platform Level Up solenoid
wiring
2. Replace Platform Level Up solenoid
3. Replace Lower Control
038 SHORTED CIRCUIT
PLATFORM LEVEL UP
The Lower Control has detected excessive current on
the Platform Level Up solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Platform Level Up solenoid wiring
2. Faulty Platform Level Up solenoid
3. Faulty Lower Control
1. Repair or replace Platform Level Up solenoid
wiring
2. Replace Platform Level Up solenoid
3. Replace Lower Control
039 OPEN CIRCUIT
PLATFORM LEVEL
DOWN
The Lower Control has detected an open circuit on the
Platform Level Down solenoid output when it was
energized during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Platform Level Down solenoid wiring
2. Faulty Platform Level Down solenoid
3. Faulty Lower Control
1. Repair or replace Platform Level Down
solenoid wiring
2. Replace Platform Level Down solenoid
3. Replace Lower Control
040 SHORTED CIRCUIT
PLATFORM LEVEL
DOWN
The Lower Control has detected excessive current on
the Platform Level Down solenoid output when it was
energized during startup self diagnostics.
Possible causes include:
1. Faulty Platform Level Down solenoid wiring
2. Faulty Platform Level Down solenoid
3. Faulty Lower Control
1. Repair or replace Platform Level Down
solenoid wiring
2. Replace Platform Level Down solenoid
3. Replace Lower Control
041 OPEN CIRCUIT
PLATFORM CW
The Lower Control has detected an open circuit on the
Platform CW solenoid output when it was energized
during startup self diagnostics.
NOTE: A load of less than 70mA will be detected as an
open circuit. The typical load is approximately 800mA.
Possible causes include:
1. Faulty Platform CW solenoid wiring
2. Faulty Platform CW solenoid
3. Faulty Lower Control
1. Repair or replace Platform CW solenoid
wiring
2. Replace Platform CW solenoid
3. Replace Lower Control
042 SHORTED CIRCUIT
PLATFORM CW
The Lower Control has detected excessive current on
the Platform CW solenoid output when it was energized
during startup self diagnostics.
Possible causes include:
1. Faulty Platform CW solenoid wiring
2. Faulty Platform CW solenoid
3. Faulty Lower Control
1. Repair or replace Platform CW solenoid
wiring
2. Replace Platform CW solenoid
3. Replace Lower Control