Varec 4532 Thermometer User Manual


 
Varec, Inc. 13
4532 Mounting
5 Mounting
5.1 Mounting instruction
Note!
1. The flexible tube length of the 4532 ATC is defined for the customer’s specifica-
tions. Before mounting, please check as follows:
The tag number (if available) on the body of the 4532 ATC
The length of the flexible tube
The number of measuring points
The intervals between measuring point
2. Mounting the 4532 ATC at a minimum of 500 mm (19.67") away from the tank shell.
This will ensure that the measurement is not influenced by changes in ambient
temperature.
3. The procedure for mounting the 4532 ATC on a tank depends on the type of tank.
Here we shall explain the procedures for a fixed roof tank and for a floating roof
tank.
In any case, the flexible tube head is mounted on the tank top as show in fig. 5.
The mounting nozzle should have a diameter of 50 mm (2") as standard.
Figure 5-1: The 4532 ATC mounting
Bolt M16
Flange for
flexible tube head
Packing
Nut M16
Washer M16
Flange for
tank top