SkyLink AD-105 Medical Alarms User Manual


 
10
LIGHTS AND SOUNDS
Below is an explanation of the lights and sounds of the Dial-Alert
LIGHTS
ACPWR light on dialer is being powered by AC adapter.
ACPWR light off dialer is not receiving any AC power.
LOBATT. light off backup battery is connected and working.
LOBATT. light on backup battery is weak, battery needs to be replaced.
ARM light on the dialer is in armed condition. It will dial out
when it receives sensor activation signal and panic
signal from Panic Devices.
ARM light off dialer will not dial out if there is sensor activation.
It will only dial out when it receives panic signal
from Panic Devices.
Keypad backlight If unit is powered by AC adapter, back light stays
on all the time.
If unit is powered by battery only, back light stays
on 10 seconds after a key is pressed.
SOUNDS
Short beep You have pressed a key in the right order.
Two short beep's 1.) When the dialer is turned on for the first time.
2.) When the pre-programmed transmitters/sensors
are deleted from the memory.
Long beep You have made a mistake.
Steady repeated beep The dialer has been triggered in DELAY mode. It
gives you time to disarm the dialer before dialing
the emergency phone numbers.
AC. PWR LO BATT. ARM
LCD DISPLAY
PANIC BUTTON
ARM BUTTON
ENTER
PROGRAM
BUTTON
NUMERIC KEYPAD
SPEAKER
11
STANDARD PROGRAMMING
There are a few programming steps you must perform before the dialer can
operate. Please follow the instructions below to program these fields, including:
- Selecting the Operation Mode
- Record voice messages
- Phone numbers you wish to dial during emergency (up to 9 phone numbers)
- Program the panic button or alarm panel to the dialer
When you first power up the Dial Alert, the display will show “not rEAdy”, that
means you don’t have a voice recording and no phone number programmed.
You must perform the following programming steps in order for the Dial Alert
to function during an emergency.
Note: During programming, there is a 10 second time out meaning each step
must be completed within 10 seconds.
SELECTING THE OPERATION MODE
As mentioned, the AD-105 works with the Control Panel SC-001 or directly
communicates with sensors, i.e. 2 operating modes are:
1) SC-001 Mode – With this mode, the dialer will be activated when it
receives a panic signal from SC-001 Control Panel. You can record
one 40-second voice message.
2) Sensor Mode – With this mode, the dialer can be activated by
preprogrammed sensors and you can record one primary voice
message (9-second) and 6 secondary messages (5 seconds each).
When you program the sensors, you can select which secondary
voice message to play when that sensor is activated.
Follow the instructions below to setup the operating mode.
1. Enter the current password (factory default password is 0000 ), then press
[PROG], display will show [P] meaning you are now in programming mode.
2. Enter [1] to select the operating mode. Display now shows [P1 2], the
most right digit represents the operating mode.
[1] – Sensor Mode
[2] – SC-001 Mode
3. Enter the desired value. For example, enter [1] if you want to set up the
dialer to work with sensors.
4. If the new setting is accepted, it will emit 2 beeps. If you don’t hear 2
beeps, that means the setting is not accepted, retry again.