SkyLink AD-105 Medical Alarms User Manual


 
21
1. Enter the current password (factory default password is 0000), then
press [PROG], display will show [P] meaning you are now in programming
mode.
2. Enter [8], display now shows [P8 1], the most right digit represents
the entry / exit delay duration.
3. Enter any number from 1 to 5, which represents the entry / exit delay
duration.
1 - Instant Arming / Instant Alarm
2 - 30 seconds entry / exit delay
3 - 45 seconds entry / exit delay
4 - 60 seconds entry / exit delay
5 - 75 seconds entry / exit delay
4. If the new setting is accepted, it will emit 2 beeps. If you don’t hear 2
beeps, that means the setting is not accepted, retry again.
Arming / Disarming
To arm the dialer, simply enter the password and then press “ ”. The
ARM LED will be on.
To disarm the dialer, simply enter the password and then press “ ”. The
ARM LED will be off.
If your dialer is working directly with a control panel, there is no need to
arm the dialer. The dialer will dial out regardless if it is armed or not when
it receives a panic signal from the control panel.
ADVANCED PROGRAMMING
If you have sensor(s) programmed to the Dial Alert, you should arm the Dial
Alert if you want to receive notification when the sensor is activated. If the
Dial Alert is not armed, sensor activation will not trigger the dialer. Therefore,
please arm the system when you want to be notified of sensor activation,
such as when you are away from home. If you are home, you may disarm
the Dial Alert if notification is not needed.
20
3. Enter [1] to disable universal dial tone meaning a proper dial tone must
be presented before dialing, or [2] to enable universal dial tone, so the
Dial Alert will dial regardless of the dial tone.
4. If the new setting is accepted, it will emit 2 beeps. If you don’t hear 2
beeps, that means the setting is not accepted, retry again.
Pick up Pause Period
Pick up Pause allows you to have a pause period after the recipient picks
up the call. This is useful if you are sending a numeric message to a
pager or sending a voice message to an answering machine. You may
define the pause period from 1 sec to 9 seconds. To change the setting,
follow the instructions below.
1. Enter the current password (factory default password is 0000), then
press [PROG], display will show [P] meaning you are now in
programming mode.
2. Enter [9], display now shows [P9 5], the most right digit represents
the pick up pause duration.
3. Enter any number from 1 to 9, which represents the pick up pause
duration, i.e. enter [1] for a 1-second pause, enter [7] for a 7-second pause.
Press [ ] to confirm your entry.
4. If the new setting is accepted, it will emit 2 beeps. If you don’t hear 2
beeps, that means the setting is not accepted, retry again.
ADVANCED PROGRAMMING
Entry / Exit Delay – For Sensor Mode
Entry / Exit Delay is used when you use the dialer in Sensor Mode when it
is communicating with individual sensors as an alarm panel. You may arm
and disarm the dialer so that sensors can communicate with the dialer.
When you arm the system, you get an exit delay to leave the premises.
The dialer will start monitoring the sensors after the exit delay, meaning
after the exit delay, any triggered sensor will activate the dialer.
Entry delay is the amount of time you have to disarm the dialer after you
activate a sensor when coming back home. You may trigger a sensor
when you come back home and the dialer will start the entry delay. You
must disarm the system during the entry delay period in order for the
dialer not to dial out.
To program the entry delay and exit delay, follow the instructions below.
The values will be the same for both of these delays.