Pride Mobility Jet 10 Mobility Aid User Manual


 
Jet 10/Rev H/Feb03 www.pridemobility.com 39
X. CARE AND MAINTENANCE
n Motor noise
n Frayed harnesses
n Cracked or broken connectors
n Uneven wear on any of the tires
n Jerky motion
n Pulling to one side
n Bent or broken wheel assemblies
n Does not power up
n Powers up, but does not move
CORRECTIVE MAINTENANCE
If the battery condition meter does not light up when you turn on the power:
n Check the 9-pin controller connector and the charger harness connector. See figures 9 and 10. Make sure
they are tight.
n Check the circuit breaker. Reset it if necessary.
n Check the battery connections.
If the above conditions prove normal, you can load test the batteries with a battery load tester. These testers are
available at automotive parts stores. Disconnect both batteries before load testing and follow the directions that
come with the load tester. If either one of the batteries fails the load test, replace both of them. If your Jet 10 still
does not power up, contact your authorized Pride provider.