Golden Technologies GP160 Wheelchair User Manual


 
LiteRider PTC_Owner’s Manual Rev A_121911
VII. OPERATION
DIAGNOSTICS/TROUBLESHOOTING
Below are a list of trouble-shooting actions. Try to use this list before you contact your
Golden Technologies representative. Go to the number on the list which matches the
number of flashing LEDs and follow the instructions. If the problem persists after you
made the checks described, contact your Golden Technologies representative for further
assistance.
1 LED - The battery needs charging or there is a bad connection to the battery. Check the
connections to the battery. If the connections are good, try charging the battery.
2 LEDs - The left hand motor has a bad connection. Check the connections to the left hand
motor.
3 LEDs - The left hand motor has a short circuit to a battery connection. Contact your
Golden Technologies representative.
4 LEDs - The right hand motor has a bad connection. Check the connections to the right
hand motor.
5 LEDs - The right hand motor has a short circuit to a battery connection. Contact your
Golden Technologies representative.
6 LEDs - The wheelchair is being prevented from driving by an external signal. One
possibility is the battery charger is connected. Disconnect the charger.
7 LEDs - A joystick fault is indicated. Make sure that the joystick is in the center position
before switching on the control system.
8 LEDs - A control system fault is indicated. Make sure that all connections are secure.
9 LEDs - The parking brakes have a bad connection. Check the parking brake and motor
connections. Make sure the control system connections are secure.
10 LEDs - An excessive voltage has been applied to the control system. This is usually
caused by a poor battery connection. Check the battery connections.
25