15
Intrinsically Safe Parameters
U
i
/V
MAX
= 35VDC
I
i
/I
MAX
= 100mA
C
i
= 0
L
i
= 500 µH
Input Power:
10 to 35VDC range; 3.5 to 22mA loop powered
Output Current:
(600 max. @ 24VDC) (120 max. @ 10VDC)
Signal Range 3.5 to 22mA
Fault 3.5mA
Start-up 3.6mA
Calibration 3.75mA
Detection Range 4 to 20mA
Over-range 22mA
Electrical Classification:
Class I, Divisions 1 & 2, Groups A, B, C & D;
Class I, Zone 0, AEx ia IIC T6; EX ia IIC T6; Eex ia IIC T6
Class II, Groups E, F & G,
Class III,
IP67, Type 4X
RFI/EMI Protection:
Complies with EN50081-2, EN50082-2
Status Indicator:
Liquid Crystal Display with Normal, Fault, and Calibration cues
5.1.4 Environmental Specifications
Operating Temperature Range:
-4°F to +122°F (-20°C to +50°C)
Storage Temperature Range:
-4°F to +122°F (-20°C to +50°C)
Humidity Range:
0 to 99% relative humidity non-condensing
Pressure Range:
Atmosphere ± 10%