2 OP-01 RS232 / RS485 Interface Function
Setting
Parameter
Code
Function
Parameter
Description
Default
Setting
0 Display Correspondingly
1 Gross Weight
2 Net Weight
3 Tare
4 Weight Accumulation
5 Times Accumulation
RS1-00
Information
Pattern
6 Output with Date & Time
0
0 Continuous Transmission
1 Auto Transmission
2 Press or to transmit
3 Command Mode (no address)
RS1-01
Transmission
Method
4 Command Mode (with address)
0
0 1200
1 2400
2 4800
3 9600
RS1-02
Transmission
Rate
4 19200
1
0 N, 8, 1
No Parity
8 Bits Length
1 Stop Bit
1 O, 7, 1
Odd Parity,
7 Bits Length,
1 Stop Bit
RS1-03
Parity
Bit Length
Stop Bit
2 E, 7, 1
Even Parity,
7 Bits Length,
1 Stop Bit
2
0 Continuous Output
RS1-04
Unstable or
Over Load
1 Stop Output
0
0 Positive (over + 10D)
RS1-05
Auto
Transmission
Condition
1
Positive/negative
(over + 10D, under - 10D)
0
RS1-06
Command
Address
00
99
Available only if RS1-
01 setting is 4
0
0 Standard Format
RS1-07
Output
Format
1
UMC 600
0
F2
4
F1