Excell Precision FM Scale User Manual


 
EXCELL PRECISION CO., LTD.
FM User Manual SME300000119
19
2 Internal Function Parameter Description
Setting
Parameter
Code
Function
Parameter
Description
Default
Setting
0 ON
CFN-00
Tare or Zero
Function under
Unstable Status
1 OFF
0
0 OFF
CFN-01
Re-zeroing after
Turning on
1 ON
0
CFN-02 Re-zero Range
0% ~ 30%
0%: Full range re-zero
1% ~ 30%:
Capacity × ± setting value%
0
CFN-03 Filter Strength 0 ~ 5 Strength increases by number 2
0 No limit
1 20 times/sec.
2 10 times/sec.
CFN-04
AD Sampling
Rate
3 5 times/sec.
2
0 OFF
1
Mode 1: No weight display
under unstable status
CFN-05
Animal Scale
Mode
2
Mode 2: Weight display whether
under stable or unstable status
0
CFN-06
Animal Scale
Stable Range
0 ~ 100 Mode 2: Stable Range Setting 30
0 8 times
1 16 times
2 32 times
3 64 times
CFN-07
Animal Scale
Sampling
Frequency
4 128 times
2
0 Multi-interval
CFN-08
Dual Range
Resolution
Setting
1 Multi-range
0
CFN-09
Dual Range
Resolution
Middle Point
Setting
0 ~ 65535 5000