SETTING GATE LIMITS (continued)
23
D3/D5 ONLY (PAGE 23, 24, 25)
- Press the TEST pushbutton while monitoring LED L1.
- When L1 flashes once, release TEST pushbutton. L2 will go out,
L1 will continue to flash once per second. Controller is now in MENU 1
which sets gate limits.
NB. Understand the procedure detailed on page 24 before continuing.
The controller is about to perform the fully automatic setup routine.
NB. Ensure you follow the correct procedure!
The procedure for setting D3/D5 and A5 motors is DIFFERENT.
The A5 limits have to be set manually (see page 25 and 26), while
the D3/D5 motors set their limits automatically (see page 21 to 23).
CP80/CP81
control card
L1
L2
STATUS
TEST
SET
START AUTOMATED GATE LIMITS ROUTINE
- Press TEST pushbutton until STATUS LED illuminates.
- AUTOMATIC set up routine (described on page 24) starts as soon as TEST
button is released.
CP80/CP81
control card
L1
L2
STATUS
TEST
SET